Various noise removal design configurations

SNR of the modified reconstruction signal (dB)

ΔSNR (dB)

512 points Hanning window One-half overlapped data buffers No frame averaging

13.1032

0.0784

512 points Hanning window One-half overlapped data buffers 3 frames averaging

13.0085

−0.0163

512 points Hanning window One-half overlapped data buffers 6 frames averaging

12.9394

−0.0854

512 points Hanning window One-fourth overlapped data buffers No frame averaging

5.1722

−7.8526

512 points Hanning window One-fourth overlapped data buffers 3 frames averaging

5.8646

−7.1602

512 points Hanning window One-fourth overlapped data buffers 6 frames averaging

6.5488

−6.476